Détails sur le produit
Diamètre du conducteur mesurable 0,177 po ou 4,5 mm maximum Température de fonctionnement -10 à 50°C
Température de stockage -25 à 60°C Indice IP Ip40
Laisser un message
Description de produit

Product overview: Fluke 771 Milliamp Process Clamp Meter

Save time by measuring 4-20 mA signals without breaking the loop

The Fluke 771 delivers all the basic functionality you would expect in a milliamp clamp meter. It measures 4-20 mA signals without "breaking the loop," allowing you to measure low level DC current without having to take systems offline for troubleshooting, saving downtime and money. You can also use it to measure output signals from transmitters without breaking the loop when maintaining and troubleshooting process and automation equipment. This saves time and avoids disrupting critical processes so you can avoid expensive downtime. You can also measure 10 to 50 mA signals in older control systems using the 99.9 mA range.

Added convenience

Designed to make troubleshooting easier, the Fluke 771 includes a detachable clamp that can be attached to the wire you're testing while you move the meter—connected by the extension cable—to a better viewing position. This is especially helpful for taking readings in tight locations. With the dual backlit display showing both the mA measurement and the percent of a 4 to 20 mA span you can quickly understand what your system is doing, and a built-in LED spotlight lets you illuminate hard to see wire in dark enclosures. You can also capture and display changing measurements using the Hold function making it easier to verify and record measurements.

 

Specifications: Fluke 771 Milliamp Process Clamp Meter

Specifications
Diameter of measurable conductor 0.177 in or 4.5 mm max
Operating temperature -10 to 50°C
Storage temperature -25 to 60°C
Operating humidity < 90% @ < 30°C, < 75% @ 30 to 55°C
Operating altitude 0 to 2000 m
IP rating IP 40
Size 59 x 38 x 212 mm (2.32 x 1.5 x 8.35 in)
Weight 260 G, (9.1 oz)
Vibration Random 2 g, 5 to 500 Hz
Shock 1 m drop test (except the jaw)
EMI/RFI Meets EN61326-1
For current measurement w/ JAW, add 1 mA to
specification for EMC field strengths of 1 V/m up to 3 V/m.
Temperature coefficient 0.01% °C
(< 18°C or > 28°C)
Power, battery life (2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical
Warranty Three years for electronics
One year for cable and clamp assembly
Functional Specifications
mA measurement
(measured by clamp)
Resolution / range 0 to 20.99 mA
Accuracy 0.2% + 2 counts
Resolution / range 21.0mA to 100.0 mA
Accuracy 1% + 5 counts